Add to Cart
Technical parameters | SUN2000-5KTL-M1 | SUN2000-6KTL-M1 | SUN2000-8KTL-M1 | SUN2000-10KTL-M1 | SUN2000-12KTL-M1 | |||||
Efficiency | ||||||||||
Maximum efficiency | 98.4% | 98.6% | 98.6% | 98.6% | 98.6% | |||||
The input | ||||||||||
Recommended max. PV power 1 | 7500wp | 9000wp | 12000wp | 15000wp | 18000wp | |||||
Max. input voltage 2 | 1100V | |||||||||
Start voltage | 200v | |||||||||
Max. input current per MPPT | 11A | |||||||||
Maximum short circuit current | 15A | |||||||||
Operating voltage range 3 | 140V~980V | |||||||||
Rated input voltage | 600V | |||||||||
Maximum input number | 2 | |||||||||
Max. input number per MPP tracker | 2 | |||||||||
Input (DC Battery) | ||||||||||
Compatible Battery | HUAWEI Smart String ESS 5kWh – 30kWh | |||||||||
Operating voltage range | 600 V ~ 980 V | |||||||||
Max operating current | 16A | |||||||||
Max charge Power | 10,000 W | |||||||||
Max discharge Power | 5,500 W | 6,600 W | 8,800 W | 10,000 W | 10,000 W | |||||
The output | ||||||||||
Grid connection | Three-phase | |||||||||
Rated output | 5,000W | 6,000W | 8,000W | 10,000W | 12,000W | |||||
Maximum apparent power | 5,500VA | 6,600VA | 8,800VA | 11,000VA | 12,000VA | |||||
Maximum active power | 5,000W | 6,000W | 8,000W | 10,000W | 12,000W | |||||
Rated output voltage | 220Vac/380Vac,230vAC/400Vac,3W/N+PE | |||||||||
Output voltage frequency | 50HZ/60HZ | |||||||||
Maximum output current | 8.5A | 10.1A | 13.5A | 16.9A | 18.4A | |||||
Max. total harmonic distortion | <3% | |||||||||
Output (Backup Power via Backup Box-B1) | ||||||||||
Maximum apparent power | 3,300 VA | |||||||||
Rated output voltage | 220 V / 230 V | |||||||||
Maximum output current | 15 A | |||||||||
Power factor range | 0.8 leading ... 0.8 lagging | |||||||||
Features & Protections | ||||||||||
Input-side disconnection device | Yes | |||||||||
Anti-Islanding protection | Yes | |||||||||
DC reverse polarity protection | Yes | |||||||||
Insulation monitoring | Yes | |||||||||
DC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | |||||||||
AC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | |||||||||
Residual current monitoring | Yes | |||||||||
AC overcurrent protection | Yes | |||||||||
AC short-circuit protection | Yes | |||||||||
AC overvoltage protection | Yes | |||||||||
Arc fault protection | Yes | |||||||||
Ripple receiver control | Yes | |||||||||
Integrated PID recovery | Yes | |||||||||
Battery reverse charging from grid | Yes | |||||||||
Nighttime Power Consumption | Yes | |||||||||
DC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | |||||||||
AC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | |||||||||
AC overcurrent protection | Yes | |||||||||
AC short-circuit protection | Yes | |||||||||
AC overvoltage protection | Yes | |||||||||
Over-heat protection | Yes | |||||||||
Battery reverse charging from grid | Yes | |||||||||
Arc fault protection | Yes | |||||||||
Operating temperature range | -25 ~ +60 °C | |||||||||
Relative operating humidity | 0 %RH~100 %RH | |||||||||
Max. operating altitude | 4,000 m (13,123 ft.) (Derating above 2000 m) | |||||||||
Cooling | Natural convection | |||||||||
Display | LED indicators; integrated WLAN + FusionSolar APP | |||||||||
Communication | RS485, WLAN via inverter built-in WLAN module Ethernet via Smart Dongle-WLAN-FE (Optional); 4G / 3G / 2G via Smart Dongle-4G (Optional) | |||||||||
Weight (incl. mounting bracket) | 12.0 kg (26.5 lb) | |||||||||
Dimension (incl. mounting bracket) | 365mm * 365mm * 156 mm (14.4 x 14.4 x 6.1 inch) | |||||||||
Degree of protection | IP65 | |||||||||
Optimizer Compatibility | ||||||||||
DC MBUS compatible optimizer | SUN2000-450W-P | |||||||||
Standard Compliance (more available upon request) | ||||||||||
Safety | EN/IEC 62109-1, EN/IEC 62109-2 | |||||||||
Grid connection standards | G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777.2, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727, IEC62116 | |||||||||
*1 Inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers. *2 The maximum input voltage and operating voltage upper limit will be reduced to 495 V when inverter connects and works with LG battery.*3 2,500 W @ 5kWh HUA WEI ESS battery |