Add to Cart
Item | Specification | ||
Cabinet installation standards | It can be installed in a 19-inch standard cabinet with a depth not less than 1200 mm (47.24 in.). | ||
By default, a Huawei A612 cabinet (1.2 m deep x 2.2 m high) is installed. Huawei acoustic doors are optional. The depth of the acoustic door is 200 mm, and the depth of the device is 1400 mm after the acoustic doors are installed. Note: The cabinet code is 02116153 (CR8B22A612C0). | |||
Dimensions without packaging (H x W x D) [mm(in.)] | 1436 mm (32.3U) x 442 mm x 1033 mm (56.54 in. x 17.40 in. x 40.67 in.) (dimensions of the chassis body) | ||
1436 mm (32.3U) x 442 mm x 1144 mm (56.54 in. x 17.40 in. x 45.04 in.) (including the chassis front and rear decorating parts and cable tray) | |||
Dimensions with packaging (H x W x D) [mm(in.)] | 1695 mm x 770 mm x 1350 mm (66.73 in. x 30.31 in. x 53.15 in.) | ||
Chassis height [U] | 32.3 U | ||
Weight without packaging [kg(lb)] | 244.8 kg (539.69 lb) | ||
Weight with packaging [kg(lb)] | 315.6 kg (695.78 lb) | ||
Weight without packaging (full configuration) [kg(lb)] | [LPUI-4T boards are fully configured]: 666.1 kg ( 1468.5 lb) | ||
[LPUI-14.4T boards are fully configured]: 707.7 kg ( 1558.9 lb) | |||
Typical power consumption (with configuration) [W] | [estimated value when LPUI-4T boards are fully configured]: 24015 W | ||
[estimated value when LPUI-14.4T boards are fully configured]: 35965 W | |||
Typical heat dissipation (with configuration) [BTU/hour] | [estimated value when LPUI-4T boards are fully configured]: 77913 BTU/hour | ||
[estimated value when LPUI-14.4T boards are fully configured]: 116684 BTU/hour | |||
MTBF [year] | 18.53 year | ||
MTTR [hour] | 0.5 hour | ||
Availability | 0.99999 | ||
Power supply mode | AC built-in | ||
Maximum number of power chassis inputs | (40 channels/PEM) x 1 PEM = (2 channels/PM) x 20 PMs x 1 PEM = 40 channels | ||
Rated input voltage [V] | AC: 200 V to 240 V | ||
HVDC: 240 V/380 V | |||
Input voltage range [V] | AC: 176 V to 290 V | ||
HVDC: 188–400V | |||
Maximum input current [A] | AC: 16 A per module | ||
HVDC: 14 A per module | |||
Maximum input cable size [mm²] | 2.5 mm² | ||
Front-end circuit breaker/fuse [A] | For AC: | ||
UPS power distribution: two 16 A inputs per module | |||
Mains power distribution: two 20 A inputs per module | |||
AC chassis: 20 PMs, requiring 40 channels of 16 A. By default, 16 PMs are configured for the chassis, requiring 32 channels of 16 A. | |||
For HVDC: | |||
Two 16 A inputs per module | |||
HVDC device: 20 PMs, requiring 40 channels of 16 A. By default, 16 PMs are configured for the device, requiring 32 channels of 16 A. | |||
Heat dissipation mode | air cooling | ||
Airflow direction | Front-to-back | ||
Number of slots | 26 | ||
Number of service board slots | 16 | ||
Switching capacity | 692.60 Tbit/s | ||
Redundant MPUs | 1:01 | ||
Redundant Switch fabrics | 7+1 | ||
Redundant power supply | 19+1 | ||
Redundant fans | Three module frames. The system can work for a short period of time when a single fan fails. (The operating temperature is 40°C.) | ||
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) | ||
Short-term operating temperature [°C(°F)] | –5°C to +50°C (23°F to 122°F) | ||
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour | ||
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | ||
Long-term operating relative humidity [RH] | 5% to 85%, non-condensing | ||
Short-term operating relative humidity [RH] | 5% to 95%, non-condensing | ||
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing | ||
Long-term operating altitude [m(ft.)] | ≤ 4000 m (If the altitude is between 1800 m and 5000 m, the operating temperature decreases by 1°C for each additional 220 m.) | ||
Storage altitude [m(ft.)] | < 5000 m |