Add to Cart
superior quality for ethernet router ME60-X16A Industry Routers | ||
Wide [mm] | 442 mm | |
Depth [mm] | 650 mm | |
Height [mm] | 1778 mm | |
Chassis height [U] | 40 U | |
Weight without packaging [kg(lb)] | 142.1 kg (313.33 lb) | |
Weight without packaging (full configuration) [kg(lb)] | [400G bundle]356 kg (784.98 lb) [1T bundle] 399.4 kg (880.68 lb) | |
Typical power consumption (with configuration) [W] | 7720 W (fully configured with BSUF-240s) 9040 W (fully configured with BSUF-480s) 12390 W (fully configured with MSUI-1Ts) | |
Typical heat dissipation (with configuration) [BTU/hour] | 25046.9 BTU/hour (fully configured with BSUF-240s) 29329.6 BTU/hour (fully configured with BSUF-480s) 40198.4 BTU/hour (fully configured with MSUI-1Ts) | |
Power supply mode | DC built-in | |
Rated input voltage [V] | –48 V/–60 V | |
Input voltage range [V] | –40 V to –72 V | |
Maximum input current [A] | 63 A/single-module | |
Number of service board slots | 16 | |
Number of slots | 22 | |
Redundant MPUs | 1:1 | |
Redundant Switch fabrics | 3+1 | |
Redundant fans | [400G bundle] 2 partitions; 2 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) | |
Redundant power supply | [400G bundle]6+1 [1T bundle] 9+1 | |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) | |
Maximum number of power chassis inputs | (8 channels/PEM)*4 PEM=(2 channels/PM)*4 PM*4 PEM=32 channels | |
Maximum input cable size | 35 mm²/channel | |
Front-end circuit breaker/fuse | 2 channels of 63 A/single-module [400G bundle] DC device: 7 PMs, with a total of 14 channels of 63 A [1T bundle] DC device: 10 PMs, with a total of 20 channels of 63 A | |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) | |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) | |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) | |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) | |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing | |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing | |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing | |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) | |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) | |
MTBF [year] | 36.39 | |
MTTR [hour] | 0.5 | |
Availability | 0.999998431 |